Rinnai code 11: No ignition

Continuous flow hot water system (Australia), tankless water heater (United States)

The heater tried to light the burner but never detected a flame, so it stopped without heating.

This needs a licensed gas technician. There are a few safe checks you can do first, marked below. Anything inside the unit is a job for a professional.

This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.

What causes it

Australian models

  1. The gas is turned off at the heater or the meter, or the LPG cylinder is empty.

    Check the gas supply is onYou can do this

    1. Check whether your other gas appliances, such as the cooktop, are working.
    2. Check the gas isolation valve to the unit is open. On most quarter-turn valves the handle sits in line with the pipe when open.
    3. On bottled LPG, check the cylinder is not empty and the cylinder valve is open.
      If you smell gas, do not use switches or flames. Leave the area and call your gas emergency line.

    Clear a Rinnai continuous flow error codeYou can do this

    1. Turn the hot water tap off, then on again.
    2. If the code is still showing, press the On/Off button on the water controller to turn it off, then on again.
    3. If it still shows, switch the heater off at the power point, wait 10 seconds, then switch it back on.
    4. If the code remains, contact Rinnai or a licensed technician with the code, model and serial numbers.
  2. Air in the gas line, the wrong gas type, or inlet gas pressure too low.

    Book a licensed gas technician

  3. A faulty igniter, a loose flame rod or earth wire, a gas valve fault, or a blocked or damaged burner.

    Book a licensed gas technician

US models

  1. The gas is turned off at the heater or the meter, or the propane tank is empty.

    Same check as above: Check the gas supply is on

    Reset the unit by cycling the powerYou can do this

    1. Switch the unit off at its isolating switch or power point.
    2. Wait at least one minute, then switch it back on and let it try to restart.
    3. If the same code comes back, stop resetting it. Write down the code, model number and serial number before calling for service.
      Repeated resets can mask a fault that needs a technician.
  2. Air left in the gas line after installation, the wrong gas type or gas-type setting, or inlet gas pressure too low.

    Book a licensed gas technician

  3. The igniter is not sparking, the electrode or flame rod is loose or carboned up, or a gas valve is faulty.

    Book a licensed gas technician

  4. Loose vent joints or vent terminal clearances that let exhaust be drawn back in.

    Book a licensed gas technician

How to read this code on your unit

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

73 models in 15 ranges
RangeModels
Heavy Duty (commercial)REU-AM3237WC (HD32e), REU-VCM2837FFC (HD28i), REU-VCM2837WC (HD28e), REU-NB3237WC-AK (Heavy Duty 32C), REU-NB3237FFC-AK, REU-NB3237WC-50-AK, REU-NB3237FFC-50-AK
InfinityREU-AM3237W (Infinity 32), REU-AM2626WDL (Infinity 26 Touch), REU-AM2626WD (Infinity 26), REU-AM2024WD (Infinity 20), REU-AM1620WD (Infinity 16), REU-AM1220WD (Infinity 12), REU-A2626WB (B26), REU-A2024WB (B20), REU-A1620WB (B16)
Infinity BREU-BM2626W (Infinity B26), REU-BM2024W (Infinity B20), REU-BM1620W (Infinity B16), REU-BM1220W (Infinity B12)
Infinity EnviroREU-E2626W (Infinity Enviro 26), REU-E1620W (Infinity Enviro 16), REU-NB3237W-AK (Infinity Enviro 32), REU-NB3237W-50-AK
Infinity internalREU-VCM2837FF (Infinity 28i)
Commercial (KB)C199i (REU-KBD3237FFUDC-US), C199e (REU-KB3237WDC-US)
KBRU80i (REU-KB2530FFUD-US), RU80e (REU-KB2530WD-US), RU90e (REU-KBD2934WD-US), RU98i (REU-KB3237FFUD-US), RU98e (REU-KB3237WD-US)
KBDRUC80i (REU-KBD2530FFUD-US), RUC90i (REU-KBD2934FFUD-US), RUC98i (REU-KBD3237FFUD-US)
KBPRUR98i (REU-KBP3237FFUD-US), RUR98e (REU-KBP3237WD-US)
KCMRUCS65i (REU-KCM2025FFU-US), RUCS75i (REU-KCM2528FFU-US), RUS65e (REU-KCM2025W-US), RUS75e (REU-KCM2528W-US)
Luxury (VC)RL75i (REU-VC2528FFUD-US), RL75i(A) (REU-VC2528FFUD-US(A)), RL75e (REU-VC2528WD-US), RL75e(A) (REU-VC2528WD-US(A)), RL94i (REU-VC2837FFUD-US), RLX94i (REU-VC2737FFUD-US), RL94e (REU-VC2837WD-US)
SENSEI commercialCU199i (REU-N3237FFC-US), CU160i (REU-N2530FFC-US), CU199e (REU-N3237WC-US), CU160e (REU-N2530WC-US)
SENSEI residentialRU199i (REU-N3237FF-US), RU180i (REU-N2934FF-US), RU160i (REU-N2530FF-US), RU130i (REU-N2024FF-US), RU199e (REU-N3237W-US), RU180e (REU-N2934W-US), RU160e (REU-N2530W-US), RU130e (REU-N2024W-US)
SENSEI residential with pumpRUR199i (REU-NP3237FF-US), RUR160i (REU-NP2530FF-US), RUR199e (REU-NP3237W-US), RUR160e (REU-NP2530W-US)
Value (VC)V53e (REU-VAM1620W-US), V53De (REU-AM1620WD-US), V65i (REU-VC2025FFU-US), V65e (REU-VC2025W-US), V75i (REU-VC2528FFU-US), V75e (REU-VC2528W-US), V94i (REU-VC2837FFU-US), V94Xi (REU-VC2737FFU-US), V94e (REU-VC2837W-US)

Where this comes from

Checked against the manufacturer's manual on 9 October 2026.

Report a mistake on this page

Other Rinnai tankless water heater codes

Code Meaning What you can do
02 Burner did not light during freeze protection Safe checks first, then a pro
03 Power cut during bath fill You can often fix it
05 Bypass flow control failure Safe checks first, then a pro
10 Air intake, flue or condensate blockage Safe checks first, then a pro
12 Flame failure or low gas flow Safe checks first, then a pro
13 Combustion fault Safe checks first, then a pro
14 Overheat safety device tripped Call a pro
15 Venturi control failure Safe checks first, then a pro
16 Over-temperature shutdown Safe checks first, then a pro
17 Venturi blockage Safe checks first, then a pro
18 Gas valve adjustment limit Call a pro
19 Electrical earth fault Call a pro