Rinnai code 71: Gas solenoid valve failure

Continuous flow hot water system (Australia), tankless water heater (United States)

A gas solenoid valve circuit is not responding correctly.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

This involves the gas supply or burner. Only a licensed technician should open the unit or work on gas parts.

What causes it

Australian models

  1. A loose or damaged gas control wire, a grounded heater circuit, or a failed control board.

    Book a licensed gas technician

US models

  1. On SENSEI models, the single DIP switch on the control board was left ON.

    Book a licensed gas technician

  2. Damaged solenoid wiring, moisture in the gas valve tubing, a failed gas valve, or a failed control board.

    Book a licensed gas technician

How to read this code on your unit

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

73 models in 15 ranges
RangeModels
Heavy Duty (commercial)REU-AM3237WC (HD32e), REU-VCM2837FFC (HD28i), REU-VCM2837WC (HD28e), REU-NB3237WC-AK (Heavy Duty 32C), REU-NB3237FFC-AK, REU-NB3237WC-50-AK, REU-NB3237FFC-50-AK
InfinityREU-AM3237W (Infinity 32), REU-AM2626WDL (Infinity 26 Touch), REU-AM2626WD (Infinity 26), REU-AM2024WD (Infinity 20), REU-AM1620WD (Infinity 16), REU-AM1220WD (Infinity 12), REU-A2626WB (B26), REU-A2024WB (B20), REU-A1620WB (B16)
Infinity BREU-BM2626W (Infinity B26), REU-BM2024W (Infinity B20), REU-BM1620W (Infinity B16), REU-BM1220W (Infinity B12)
Infinity EnviroREU-E2626W (Infinity Enviro 26), REU-E1620W (Infinity Enviro 16), REU-NB3237W-AK (Infinity Enviro 32), REU-NB3237W-50-AK
Infinity internalREU-VCM2837FF (Infinity 28i)
Commercial (KB)C199i (REU-KBD3237FFUDC-US), C199e (REU-KB3237WDC-US)
KBRU80i (REU-KB2530FFUD-US), RU80e (REU-KB2530WD-US), RU90e (REU-KBD2934WD-US), RU98i (REU-KB3237FFUD-US), RU98e (REU-KB3237WD-US)
KBDRUC80i (REU-KBD2530FFUD-US), RUC90i (REU-KBD2934FFUD-US), RUC98i (REU-KBD3237FFUD-US)
KBPRUR98i (REU-KBP3237FFUD-US), RUR98e (REU-KBP3237WD-US)
KCMRUCS65i (REU-KCM2025FFU-US), RUCS75i (REU-KCM2528FFU-US), RUS65e (REU-KCM2025W-US), RUS75e (REU-KCM2528W-US)
Luxury (VC)RL75i (REU-VC2528FFUD-US), RL75i(A) (REU-VC2528FFUD-US(A)), RL75e (REU-VC2528WD-US), RL75e(A) (REU-VC2528WD-US(A)), RL94i (REU-VC2837FFUD-US), RLX94i (REU-VC2737FFUD-US), RL94e (REU-VC2837WD-US)
SENSEI commercialCU199i (REU-N3237FFC-US), CU160i (REU-N2530FFC-US), CU199e (REU-N3237WC-US), CU160e (REU-N2530WC-US)
SENSEI residentialRU199i (REU-N3237FF-US), RU180i (REU-N2934FF-US), RU160i (REU-N2530FF-US), RU130i (REU-N2024FF-US), RU199e (REU-N3237W-US), RU180e (REU-N2934W-US), RU160e (REU-N2530W-US), RU130e (REU-N2024W-US)
SENSEI residential with pumpRUR199i (REU-NP3237FF-US), RUR160i (REU-NP2530FF-US), RUR199e (REU-NP3237W-US), RUR160e (REU-NP2530W-US)
Value (VC)V53e (REU-VAM1620W-US), V53De (REU-AM1620WD-US), V65i (REU-VC2025FFU-US), V65e (REU-VC2025W-US), V75i (REU-VC2528FFU-US), V75e (REU-VC2528W-US), V94i (REU-VC2837FFU-US), V94Xi (REU-VC2737FFU-US), V94e (REU-VC2837W-US)

Where this comes from

Checked against the manufacturer's manual on 9 October 2026.

Report a mistake on this page

Other Rinnai tankless water heater codes

Code Meaning What you can do
15 Venturi control failure Safe checks first, then a pro
17 Venturi blockage Safe checks first, then a pro
18 Gas valve adjustment limit Call a pro
22 Gas valve adjustment fault Call a pro
52 Gas modulating valve fault Call a pro
63 Recirculation low flow Call a pro
65 Water flow control failure Safe checks first, then a pro
66 Bypass flow control fault Call a pro
70 Control board (PCB) failure Safe checks first, then a pro
72 Flame rod circuit error Call a pro
73 Burner thermocouple fault Call a pro
79 Water leak detected Safe checks first, then a pro