1. Home
  2. Rinnai
  3. tankless water heaters
  4. Code 51

Rinnai code 51: Inlet water thermistor fault

Continuous flow hot water system (Australia), tankless water heater (United States)

The sensor that measures incoming cold water temperature is giving no reading or an impossible one.

This needs a licensed gas technician. There is nothing safe to check yourself. Leave the covers on and book a professional.

What causes it

Australian models

  1. Damaged sensor wiring, or a failed inlet thermistor.

    Book a licensed gas technician

US models

  1. Loose or damaged wiring, scale on the sensor, or a failed sensor.

    Book a licensed gas technician

How to read this code on your unit

Booking a licensed gas technician

Book a licensed gas technicianlicensed gas technician

  1. Turn the unit off and leave the covers on. Gas components must only be serviced by a licensed technician.
  2. Note the code, how often it appears, and the model and serial numbers from the rating label.
  3. Book a licensed gas technician and give them those details.

Models that show this code

73 models in 15 ranges
RangeModels
Heavy Duty (commercial)REU-AM3237WC (HD32e), REU-VCM2837FFC (HD28i), REU-VCM2837WC (HD28e), REU-NB3237WC-AK (Heavy Duty 32C), REU-NB3237FFC-AK, REU-NB3237WC-50-AK, REU-NB3237FFC-50-AK
InfinityREU-AM3237W (Infinity 32), REU-AM2626WDL (Infinity 26 Touch), REU-AM2626WD (Infinity 26), REU-AM2024WD (Infinity 20), REU-AM1620WD (Infinity 16), REU-AM1220WD (Infinity 12), REU-A2626WB (B26), REU-A2024WB (B20), REU-A1620WB (B16)
Infinity BREU-BM2626W (Infinity B26), REU-BM2024W (Infinity B20), REU-BM1620W (Infinity B16), REU-BM1220W (Infinity B12)
Infinity EnviroREU-E2626W (Infinity Enviro 26), REU-E1620W (Infinity Enviro 16), REU-NB3237W-AK (Infinity Enviro 32), REU-NB3237W-50-AK
Infinity internalREU-VCM2837FF (Infinity 28i)
Commercial (KB)C199i (REU-KBD3237FFUDC-US), C199e (REU-KB3237WDC-US)
KBRU80i (REU-KB2530FFUD-US), RU80e (REU-KB2530WD-US), RU90e (REU-KBD2934WD-US), RU98i (REU-KB3237FFUD-US), RU98e (REU-KB3237WD-US)
KBDRUC80i (REU-KBD2530FFUD-US), RUC90i (REU-KBD2934FFUD-US), RUC98i (REU-KBD3237FFUD-US)
KBPRUR98i (REU-KBP3237FFUD-US), RUR98e (REU-KBP3237WD-US)
KCMRUCS65i (REU-KCM2025FFU-US), RUCS75i (REU-KCM2528FFU-US), RUS65e (REU-KCM2025W-US), RUS75e (REU-KCM2528W-US)
Luxury (VC)RL75i (REU-VC2528FFUD-US), RL75i(A) (REU-VC2528FFUD-US(A)), RL75e (REU-VC2528WD-US), RL75e(A) (REU-VC2528WD-US(A)), RL94i (REU-VC2837FFUD-US), RLX94i (REU-VC2737FFUD-US), RL94e (REU-VC2837WD-US)
SENSEI commercialCU199i (REU-N3237FFC-US), CU160i (REU-N2530FFC-US), CU199e (REU-N3237WC-US), CU160e (REU-N2530WC-US)
SENSEI residentialRU199i (REU-N3237FF-US), RU180i (REU-N2934FF-US), RU160i (REU-N2530FF-US), RU130i (REU-N2024FF-US), RU199e (REU-N3237W-US), RU180e (REU-N2934W-US), RU160e (REU-N2530W-US), RU130e (REU-N2024W-US)
SENSEI residential with pumpRUR199i (REU-NP3237FF-US), RUR160i (REU-NP2530FF-US), RUR199e (REU-NP3237W-US), RUR160e (REU-NP2530W-US)
Value (VC)V53e (REU-VAM1620W-US), V53De (REU-AM1620WD-US), V65i (REU-VC2025FFU-US), V65e (REU-VC2025W-US), V75i (REU-VC2528FFU-US), V75e (REU-VC2528W-US), V94i (REU-VC2837FFU-US), V94Xi (REU-VC2737FFU-US), V94e (REU-VC2837W-US)

Where this comes from

Checked against the manufacturer's manual on 9 October 2026.

Report a mistake on this page

Other Rinnai tankless water heater codes

Code Meaning What you can do
32 Outgoing water temperature sensor fault Call a pro
33 Heat exchanger thermistor fault Call a pro
34 Temperature sensor fault (depends on model) Call a pro
36 Lower tank thermistor fault Call a pro
38 Exhaust temperature thermistor fault Call a pro
41 Frost protection (ambient) sensor fault Call a pro
52 Gas modulating valve fault Call a pro
54 High exhaust gas temperature Safe checks first, then a pro
55 Service reminder Safe checks first, then a pro
57 Burner overheat switch open Call a pro
58 Secondary heat exchanger overheat Call a pro
61 Combustion fan failure Call a pro

See all temperature sensor fault codes on tankless water heaters across brands.